Por favor, use este identificador para citar o enlazar este ítem: http://inaoe.repositorioinstitucional.mx/jspui/handle/1009/2146
Measuring of temperatures of a candle flame using four multidirectional point-diffraction interferometers
JUAN CARLOS AGUILAR LOPEZ
Luis Raúl Berriel Valdós
J. Felix Aguilar Valdez
Acceso Abierto
Atribución-NoComercial-SinDerivadas
Tomography
Inverse problems
Interferogram processing
Point-diffraction interferometer
An optical system formed by four point-diffraction interferometers is used for measuring the temperature distribution of a candle flame. It is assumed that the phase can be expressed in terms of the Radon transform, and it is processed with a tomographic iterative algorithm to obtain the temperatures. The interferograms show the asymmetry of the candle flame, justifying the use of a tomographic iterative algorithm instead of the Abel inversion. The resulting temperature distribution verifies the usefulness of the proposed method. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE) [DOI: 10.1117/1.OE.52.10.104103]
Optical Engineering
2013-10
Artículo
Inglés
Estudiantes
Investigadores
Público en general
Aguilar, Juan C., et al., (2013). Measuring of temperatures of a candle flame using four multidirectional point-diffraction interferometers, Optical Engineering, Vol. 52(10):1-8
ÓPTICA
Versión aceptada
acceptedVersion - Versión aceptada
Aparece en las colecciones: Artículos de Óptica

Cargar archivos: