Por favor, use este identificador para citar o enlazar este ítem: http://inaoe.repositorioinstitucional.mx/jspui/handle/1009/2642
Modelado de la Sensibilidad Espectrofotométrica de OFIUCO
Yaritza Borroel Duran
Fernando Fabian Rosales-Ortega
Perla Carolina Garcia Flores
Acceso Abierto
Atribución-NoComercial-SinDerivadas
OFIUCO
Astronomical instrumentation
Sensitivity
Fourier transform
OFIUCO (Optical Fourier Transform Imaging Unit for Cananea Observatory) es un nuevo espectrómetro de transformada de Fourier de imagen que se instalará en el telescopio del Observatorio Astrofísico Guillermo Haro (OAGH) en Cananea, Sonora. Este instrumento se utilizará para el análisis de las líneas de emisión visibles (400 - 800 nm) en un campo de visión de 6 × 6 minutos de arco, fotografiado en un CCD de 1024 × 1024 píxeles con una escala de placa de 0.355 segundos de arco por píxel. En este trabajo hemos modelado el interferómetro de OFIUCO en Zemax con la finalidad de obtener interferogramas lo mas cercano posible a los obtenidos experimentalmente en términos de alineación y transmisión. Por otro lado, es necesario acoplarlo al plano imagen de un reductor focal conectado al telescopio de Cananea, por lo que diseñamos el acoplamiento óptico (colimadorcámara) para OFIUCO; también se diseñó una película antirreflejante (AR) para lograr una mayor transmisión en el acoplamiento y el reductor. El rendimiento se evaluó usando la configuración del detector con ruido de lectura bajo y ganancia moderada (24.5 e−/seg/píxel y 15.8 e−/ADU, respectivamente) y estimando la transmisión, la magnitud de punto cero y las magnitudes límite para fuentes puntuales. Luego, se estimó la resolución espectral mediante el criterio de Nyquist, definida por la diferencia de camino óptico (OPD, por sus siglas en inglés) del espejo móvil (el espejo móvil ofrece un recorrido máximo de 52 mm) y el número de orden. Por último, obtuvimos el alcance de OFIUCO para fuentes extendidas, a través de una comparación con los datos obtenidos por un instrumento que opera con la misma configuración.
OFIUCO (Optical Fourier Transform Imaging Unit for Cananea Observatory) is a new image Fourier transform spectrometer to be installed at the Guillermo Haro Astrophysical Observatory (OAGH) telescope in Cananea, Sonora. This instrument will be used for the analysis of visible emission lines (400 - 800 nm) in a field of view of 6 × 6 arc minutes, photographed on a CCD of 1024 × 1024 pixels with a scale plate of 0.355 arcsec per pixel. In this work we have modeled the OFIUCO interferometer in Zemax in order to obtain interferograms as close as possible to those obtained experimentally in terms of alignment and transmission. On the other hand, it is necessary to couple it to the image plane of a focal reducer connected to the Cananea telescope, so we designed the optical coupling (collimator-camera) for OFIUCO; An anti-reflective (AR) film was also designed to achieve a higher transmission at the coupling and reducer. The performance was evaluated using the detector configuration with low read noise and moderate gain (24.5 e−/sec/pixel y 15.8 e−/ADU, respectively) and estimating the transmission, the zero point magnitude and limiting magnitudes for point sources. Then, the spectral resolution was estimated using the Nyquist criterion, defined by the optical path difference (OPD) of the moving mirror (the moving mirror offers a maximum travel of 52 mm) and the order number. Finally, we obtained the scope of OFIUCO for extended sources, through a comparison with the data obtained by an instrument that operates with the same configuration.
Instituto Nacional de Astrofísica, Óptica y Electrónica
2021-03
Tesis de maestría
Español
Estudiantes
Investigadores
Público en general
Borroel Duran Y. R., (2021), Modelado de la Sensibilidad Espectrofotométrica de OFIUCO, Tesis de Maestría, Instituto Nacional de Astrofísica, Óptica y Electrónica.
OTRAS ESPECIALIDADES ASTRONÓMICAS
Versión aceptada
acceptedVersion - Versión aceptada
Aparece en las colecciones: Maestría en Astrofísica

Cargar archivos:


Fichero Tamaño Formato  
BORROELDYR_MA.pdf11.95 MBAdobe PDFVisualizar/Abrir